EasyPro Pond Products https://easypro.com/ Tue, 18 Feb 2025 20:04:46 +0000 en-US hourly 1 https://easypro.com/wp-content/uploads/2024/08/cropped-EasyPro®_Logo_SocialMediaOnly_Button_Color_RGB-32x32.png EasyPro Pond Products https://easypro.com/ 32 32 Starburst Mini Fountain Instructions https://easypro.com/starburst-mini-fountain-instructions/?utm_source=rss&utm_medium=rss&utm_campaign=starburst-mini-fountain-instructions https://easypro.com/starburst-mini-fountain-instructions/#respond Tue, 18 Feb 2025 20:04:43 +0000 https://easypro.com/?p=65413 MWF36 Instructions for Operation • Safety • Warranty Thank you for purchasing the Starburst Mini Pond Fountain. This fountain is powered by an asynchronous mag drive pump that is designed for continuous duty. Since the motor is oil-free, it’s safe for plants, fish, and wildlife. The fountain float contains six built-in super bright LED lights […]

The post Starburst Mini Fountain Instructions appeared first on EasyPro Pond Products.

]]>
MWF36

Instructions for Operation • Safety • Warranty

Thank you for purchasing the Starburst Mini Pond Fountain. This fountain is powered by an asynchronous mag drive pump that is designed for continuous duty. Since the motor is oil-free, it’s safe for plants, fish, and wildlife. The fountain float contains six built-in super bright LED lights that provide a brilliant nighttime display. To use this product safely and to maximum benefit, be sure to read and follow these instructions. Keep a copy of the instructions for reference.


Box Contents

  • 1 Asynchronous Mag Drive Pump with 30′ Cord
  • 1 Fountain Float with 6 Built-In LED Lights and 30′ Cord
  • 1 Transformer
  • 3 Stainless Thumb Bolts
  • 2 Mooring/Anchor Ropes
Box Contents

Safety & Electrical Connections

  1. Always disconnect the electrical supply before handling, maintaining, repairing, or installing any pond equipment.
  2. Keep out of the reach of children.
  3. Always make sure you know the correct amps and voltage required before installing.
  4. Use a dedicated power outlet only. Sharing the outlet with other equipment may cause overheating and fire.
  5. Always connect to a Ground Fault Circuit (GFCI) to prevent electrical shock. Never submerge connecting power cable plug in water.
  6. Never let the pump run without water as this will damage the impeller, overheat, and possibly burn out the pump. This pump must stay submerged entirely when operating. Running the pump low on water will cause overheating, premature failure, and will void the warranty.
  7. Do not use this product in bathrooms or swimming pools. For use with fresh water only.
  8. Do not use in water over 95°F (35°C).
  9. All electrical work must be performed by a qualified technician. Always follow the National Electrical Code (NEC) or the Canadian Electrical Code as well as all local, state, and provincial codes. Code questions should be directed to your local electrical inspector. Failure to follow electrical codes and OSHA safety standards may result in personal injury or equipment damage. Failure to follow manufacturer’s installation instructions may result in electrical shock, fire hazard, personal injury or death, damaged equipment, provide unsatisfactory performance and may void manufacturer’s warranty.
  10. Do not carry or lift the pump by the power cord.
  11. Never use an extension cord or tamper with the power cord. The power cord should not become bent, twisted, abraded, or cut. A damaged cable may cause electric leakage, shock, or fire. The power cord cannot be replaced, and the unit should be replaced if the cord becomes damaged.
  12. Do not remove the pump housing during operation of the pump.

Assembly, General Installation, Operation

  1. Slide the fountain float down over the top of the pump until it sits securely.
  2. Secure the float by inserting the three thumb bolts into every other hole. Finger-tighten the bolts until the tops of the bolts are flush with the inner rim of the float. Do not over-tighten.
  3. Connect the light’s power cord to the transformer.
  4. Connect the mooring/anchor ropes to the float.
  5. Place the fountain in your pond, in a location with a consistent depth of 18″ or more. Secure with the mooring/anchor rope.
  6. Plug the pump and light cords into a GFCI outlet. (See Safety and Electrical Connections for important instructions about power connections.)
  7. Set the timer for the fountain and lights if desired (purchase separately).

Service & Maintenance

Disconnect all power supplies before inspection or service to avoid possible electrical shock.

  1. Regularly inspect and clean the pump housing to ensure that it is clear of debris or algae which can reduce the flow.
  2. Be sure the pump housing is closed and properly latched to prevent debris from entering the pump.
  3. Check the water level daily to ensure the pump remains fully submerged.
  4. If the pump is left in water but not operating regularly, test run it at least once a week.
  5. Once per season, the unit should be cleaned of any debris build-up or mineral deposits on the impeller assembly and housing. Areas with hard water may require more frequent cleaning. To access the impeller:
    • A. Remove the zip tie securing the bottom screen.
    • B. Gently twist the bottom screen from the pump.
    • C. Inspect the impeller and chamber.
    • D. Clean using water and a damp cloth or sponge.
    • A vinegar mixture may help remove hard deposits.
  6. If the impeller is damaged, replace it with a new impeller.
  7. Be sure the pump housing is closed and properly latched before returning to the pond. A zip tie is recommended to secure the unit.
  8. Cleaning the lenses on the lights will keep your nighttime display bright. Lights pop out and back into the float easily for cleaning, but they may be cleaned without removal.
  9. Winterization/Storage: When the pump is out of use for an extended time, wash and dry it, then store it indoors in a non-freezing location. It is essential to prevent any risk of the pump freezing.

EasyPro Pond Products Limited Warranty

EasyPro Pond Products (“EasyPro”) warrants to the purchaser that this product (“Product”) will be free from any mechanical or material defects for a period of one year from the date of purchase. Gaskets, impellers, and bulbs are considered wearable items and are not covered under this limited warranty.

This warranty only covers properly installed and maintained Products sold by authorized EasyPro Sellers who are subject to and follow EasyPro’s quality control standards. Please note that because EasyPro is unable to control the quality of Products sold by unauthorized sellers, unless otherwise prohibited by law, this warranty does not cover Products purchased from unauthorized sellers.

This warranty does not cover normal wear and tear, nor any deterioration suffered through overloading, improper use, negligence, improper installation, acts of God, or accident. Similarly, any modification made by the purchaser to the Product will cause the warranty to be null and void. This warranty does not cover any cost associated with the installation or removal of the Product subject to a warranty claim.

All returned items will be inspected to determine the cause of failure before a warranty claim is approved. The exclusive remedies provided hereunder shall, upon EasyPro’s inspection and option, be either repair or replacement of the Product or parts covered under this warranty.

Making a Claim:
A Return Authorization (RA) number must first be obtained by calling EasyPro at 800-448-3873 or via email at warranty@easypro.com. It is the purchaser’s responsibility to pay the return shipping charges. Be sure to include the RA number, original receipt, your name, return address, and phone number inside the package. No warranty claims will be honored without the original receipt that shows that your purchase was made from an Authorized EasyPro Seller. Ensure the product is properly packaged and insured for the replacement value.


Troubleshooting

Does not start

  • Make sure power cord is plugged in.
  • Check outlet GFCI or house circuit breaker.
  • Improper power supply.

Pump is running, no/low spray

  • Check pump housing or piping for obstructions.
  • Check pump housing or impeller for clogs.
  • Check if impeller is broken or stuck.
  • Water level is too low with pump sucking air.

GFCI breaker tripping

  • Power cord may be damaged and getting wet. The cord is not replaceable, so a new unit will be required.
  • Nuisance trip due to improper grounding.
  • Overloaded circuit.

Pump stops

  • Ensure pump is clear of obstructions.
  • Check that the impeller is in good condition. Replace if needed.
  • Check power supply.

The post Starburst Mini Fountain Instructions appeared first on EasyPro Pond Products.

]]>
https://easypro.com/starburst-mini-fountain-instructions/feed/ 0
LED4RL Rock Light Data Sheet https://easypro.com/led4rl-rock-light-data-sheet/?utm_source=rss&utm_medium=rss&utm_campaign=led4rl-rock-light-data-sheet https://easypro.com/led4rl-rock-light-data-sheet/#respond Tue, 18 Feb 2025 19:55:17 +0000 https://easypro.com/?p=65408 INCOGNITO ROCK LIGHT4 Watt LED EASYPRO.COM 800-448-3873 H20YEAH! Rock-Shaped – Easy to Conceal!Realistic rock cover is molded from actual rock for a natural look that blends into the landscape of ponds, waterfalls, and gardens. Super bright, warm white lights are fully submersible and may be used in or out of the water. Dimensions: LIGHT SPECS […]

The post LED4RL Rock Light Data Sheet appeared first on EasyPro Pond Products.

]]>
INCOGNITO ROCK LIGHT
4 Watt LED

EASYPRO.COM 800-448-3873

H20YEAH!

Rock-Shaped – Easy to Conceal!
Realistic rock cover is molded from actual rock for a natural look that blends into the landscape of ponds, waterfalls, and gardens.

Super bright, warm white lights are fully submersible and may be used in or out of the water.

LED4RL
  • Use in or out of water. Rated IP68
  • Design of rock cover allows user to change direction of the light beam
  • Stainless steel housing for long life. Safe for chlorine and salt water.
  • Light features optical lenses to maximize illumination
  • Designed with an added flat surface to angle the beam upward

Dimensions:

  • 5.5″ wide
  • 3.75″ tall
  • 3.25″ deep

LIGHT SPECS – LED4RL

  • Wattage: 4 watt
  • Diodes: Super bright CREE diodes proudly made in the USA
  • Light temperature: 2800K warm white
  • Color rendering index: 87
  • Light angle: 22°
  • Bulb life: up to 60,000 hours
  • Power cord: 16′ with 12V quick connect plug
  • Use with: MT10, MT20 or EPT45 transformers (not included)
LIGHT SPECS - LED4RL

The post LED4RL Rock Light Data Sheet appeared first on EasyPro Pond Products.

]]>
https://easypro.com/led4rl-rock-light-data-sheet/feed/ 0
4 Watt LED Rock Lights Instructions for Operation https://easypro.com/4-watt-led-rock-lightsinstructions-for-operation/?utm_source=rss&utm_medium=rss&utm_campaign=4-watt-led-rock-lightsinstructions-for-operation https://easypro.com/4-watt-led-rock-lightsinstructions-for-operation/#respond Tue, 18 Feb 2025 19:49:34 +0000 https://easypro.com/?p=65404 Thank you for purchasing the 4 Watt LED Rock Light from EasyPro.This light can make your fountain glow, illuminate your pond from within, highlight your waterfall from inside and outside the pond and extend the enjoyment of your water feature into the evening hours. This light may be used outside of the pond as landscape […]

The post 4 Watt LED Rock Lights Instructions for Operation appeared first on EasyPro Pond Products.

]]>
Thank you for purchasing the 4 Watt LED Rock Light from EasyPro.
This light can make your fountain glow, illuminate your pond from within, highlight your waterfall from inside and outside the pond and extend the enjoyment of your water feature into the evening hours. This light may be used outside of the pond as landscape lighting as well. Use of this low voltage light requires a transformer. (not included) Consider EasyPro transformers MT10 (2 lights), MT20 (4 lights) or EPT45 (up to 8 lights).

4 Watt LED Rock Lights Instructions for Operation

Safety and Electrical Connections

  1. Always disconnect the electrical supply before handling, maintaining, repairing or installing any pond equipment.
  2. Light(s) must be attached to a UL listed transformer. (purchase separately)
  3. Never hook the lights directly to a 110 volt or higher outlet.
  4. Connect the transformer to a 110 volt receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI).
  5. Do not use this product in bathrooms or swimming pools.
  6. All electrical work must be performed by a qualified technician. Always follow the National Electrical Code (NEC) or the Canadian Electrical Code as well as all local, state and provincial codes. Code questions should be directed to your local electrical inspector. Failure to follow electrical codes and OSHA safety standards may result in personal injury or equipment damage. Failure to follow manufacturer’s installation instructions may result in electrical shock, fire hazard, personal injury or death, damaged equipment, provide unsatisfactory performance and may void manufacturer’s warranty.

Installation

  1. Before installing the product make sure to check in the box for damaged or missing parts. Contact EasyPro immediately if pieces are missing or damaged.
  2. Be sure the power is disconnected before installing the lights.
  3. Place the light in the desired location. There are “flat” spots that allow you to more securely place the light at the desired angle.
  4. When installing the light cable, run the wire back to the transformer and remove the protective cap off of one of the terminals on the transformer. Insert the two prong plug into the terminal and screw down the nut to make a weather tight seal.
  5. To connect multiple Rock Lights together in a “daisy chain” formation, you will need a suitable transformer, lighting cable(s) and splitter(s). See back for recommended accessories.
  6. Install transformer on a timer and enjoy.

The post 4 Watt LED Rock Lights Instructions for Operation appeared first on EasyPro Pond Products.

]]>
https://easypro.com/4-watt-led-rock-lightsinstructions-for-operation/feed/ 0
PFM4 Nonwoven Material Product Specifications https://easypro.com/pfm4-nonwoven-material-product-specifications/?utm_source=rss&utm_medium=rss&utm_campaign=pfm4-nonwoven-material-product-specifications https://easypro.com/pfm4-nonwoven-material-product-specifications/#respond Tue, 18 Feb 2025 19:43:34 +0000 https://easypro.com/?p=65402 1.0 Description The PFM4 nonwoven material is constructed of polyester fibers in a textured nonwoven fabrication. 2.0 Properties PROPERTY VALUE Thickness – mm (a) 34 Weight – oz./yd.² (b) 24 Fiber type 100% recycled polyester Binder system Cross-linkable water-based latex Binder Application Spray/thermal bond Color Cream Surface area sq. ft./cubic ft. of matrix 97 Volumetric […]

The post PFM4 Nonwoven Material Product Specifications appeared first on EasyPro Pond Products.

]]>
1.0 Description


The PFM4 nonwoven material is constructed of polyester fibers in a textured nonwoven fabrication.

2.0 Properties

PROPERTYVALUE
Thickness – mm (a)34
Weight – oz./yd.² (b)24
Fiber type100% recycled polyester
Binder systemCross-linkable water-based latex
Binder ApplicationSpray/thermal bond
ColorCream
Surface area sq. ft./cubic ft. of matrix97
Volumetric displacement (ml/cu. ft.) (d)275
% of open space volume99
Toxicity testingPassed
Primary usageBiological and mechanical filtration
PackagingRolls

Note: Due to the intrinsic properties of the
material and variable conditions of use, there
may be slight variations in the specifications
and results.

3.0 Use


This material is used primarily as a component for biological and mechanical filtration units for ponds.

4.0 Construction


100% of the polyester fiber in the PFM4 nonwoven material comes from post-consumer and industrial recycled waste. The primary source of this material is recycled water and soda bottles. Only water-based latex resins are used in the manufacturing process. No phenol-formaldehyde resins are used in the binding process.

5.0 “Green” Initiative


a. Polyester fiber used in the material comes from 100% post-consumer and industrial recycled waste product.
b. Water-based latex resins are used in the manufacturing process. No phenol-formaldehyde resins are used in the binding process.
c. Plant is operating under an EPA-approved clean air permit.

6.0 Product Care


To prolong the life of the PFM4 material, it is recommended that the product be stored indoors or wrapped in UV-resistant packaging if stored outdoors.

7.0 Sizes


28″ wide x 40 linear yards(a) Thickness Tolerance:

  • ±10%
  • Test method TM-005. Thickness values are obtained using a 6¾” x 6¾” material sample placed in a calibrated high-loft meter.
  • No other measuring techniques will be considered in determining thickness unless comparable testing methods are agreed upon.

(b) Weight Tolerance:

  • ±10%

(c) Color Variation:

  • ±5% visual based on appearance standard

(d) Volumetric Displacement:
A method of measurement that involves immersing a specified volume of material under water and measuring the amount of water displaced into a graduated reservoir from an overflow tube. This method gives an accurate representation of surface area in the material by taking into account the expanded surface area of the fiber from binder and binder globules at fiber crossover points.

The post PFM4 Nonwoven Material Product Specifications appeared first on EasyPro Pond Products.

]]>
https://easypro.com/pfm4-nonwoven-material-product-specifications/feed/ 0
ECM3V Multipurpose Three Way Valve Instructions https://easypro.com/ecm3v-multipurpose-three-way-valve-instructions/?utm_source=rss&utm_medium=rss&utm_campaign=ecm3v-multipurpose-three-way-valve-instructions https://easypro.com/ecm3v-multipurpose-three-way-valve-instructions/#respond Tue, 18 Feb 2025 19:23:01 +0000 https://easypro.com/?p=65396 This three-way valve is used to control the water flow coming from your pump to: ECM3VEco-Clear Three-Way ValveInstructions for Installation • Operation Cut here for1 1/2″ tubing Cut here for2″ tubing General Installation Tips Maximum performance is achieved when used with the largest outlets and tubing sizes available. Restricting water flow with small accessories will […]

The post ECM3V Multipurpose Three Way Valve Instructions appeared first on EasyPro Pond Products.

]]>
This three-way valve is used to control the water flow coming from your pump to:

  1. control the flow of water to your filter
    or
  2. feed two water features.

ECM3V
Eco-Clear Three-Way Valve
Instructions for Installation • Operation

Cut here for
1 1/2″ tubing

Cut here for
2″ tubing


General Installation Tips

Maximum performance is achieved when used with the largest outlets and tubing sizes available. Restricting water flow with small accessories will reduce the performance of the pump.

  1. Select the step barb fitting based on the type of tubing being used.
  2. When using the step barb fitting, use a hacksaw to remove any smaller steps than the tubing being used as shown in the photos below.
  3. Be sure rubber gaskets are in place inside barbed fittings before installing on valve body.
  4. Attach the appropriate tubing to the barb fittings and secure with clamps. (clamps not included)
  5. Open the desired valve(s) for operation.
General Installation Tips

Features

  • Step barb inlet fitting for 1 1/4″, 1 1/2″, or 2″ incoming water
  • Step barb outlet fittings for use with 1″, 1 1/4″, or 1 1/2″ kink-free tubing
  • Easy-turn handles
  • Ball valves for effective flow control

INLET FITTING OUTLET FITTINGS

Cut here for
1 1/4″ tubing

Cut here for
1 1/2″ tubing


PVC Installation Tips

The valve body may be used with SCH 40 PVC fittings (sold separately) for use with flexible PVC pipe. Use 2″ female adapter on the inlet and 1.5″ female adapters on the outlets as shown in the photo.

  • Wrap valve body threads with Teflon Tape before installing female adapters.
  • Do not overtighten.
PVC installation

Winterization/Storage

When the Three-Way Valve is out of use for an extended time:

  • Wash and dry it
  • Store indoors in a non-freezing location

Valves damaged by freezing are not covered under the limited warranty.

EasyPro Pond Products Limited Warranty

EasyPro Pond Products (“EasyPro”) warrants to the purchaser that this product (“Product”) will be free from any mechanical or material defects for a period of one year from the date of purchase. Gaskets are considered wearable items and are not covered under this limited warranty. For use in freshwater only. This warranty only covers properly installed and maintained Products sold by authorized EasyPro Sellers who are subject to and follow EasyPro’s quality control standards. Please note that because EasyPro is unable to control the quality of Products sold by unauthorized sellers, unless otherwise prohibited by law, this warranty does not cover Products purchased from unauthorized sellers.

This warranty does not cover normal wear and tear, nor any deterioration suffered through overloading, improper use, negligence, improper installation, acts of God, or accident. Similarly, any modification made by the purchaser to the Product will cause the warranty to be null and void. This warranty does not cover any cost associated with the installation or removal of the Product subject to a warranty claim.

All returned items will be inspected to determine the cause of failure before a warranty claim is approved.

The exclusive remedies provided hereunder shall, upon EasyPro’s inspection and option, be either repair or replacement of the Product or parts covered under this warranty.

Making a Claim:

A Return Authorization (“RA”) number must first be obtained by calling EasyPro at 800-448-3873 or via email at warranty@easypro.com. It is the purchaser’s responsibility to pay the return shipping charges.

Be sure to include the RA number, original receipt (in the form of an invoice or sales receipt), your name, return address, and phone number inside the package. No warranty claims will be honored without the original receipt that shows that your purchase was made from an Authorized EasyPro Seller. Ensure the product is properly packaged and insured for the replacement value. Damage due to improper packaging is the responsibility of the sender.

ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE DURATION OF THE WARRANTY AS DESCRIBED ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

EasyPro shall not be held liable for any damages caused by defective components or materials of this Product; or for loss incurred because of the interruption of service; or any consequential/incidental damages and expenses arising from the production, sale, use, or misuse of this Product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

EasyPro shall not be held liable for any loss of fish, plants, or any other livestock as a result of any failure or defect of this Product.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.


The post ECM3V Multipurpose Three Way Valve Instructions appeared first on EasyPro Pond Products.

]]>
https://easypro.com/ecm3v-multipurpose-three-way-valve-instructions/feed/ 0
TB Series Pumps , Submersible Pond & Waterfall Pumps https://easypro.com/tb-series-pumps-submersible-pond-waterfall-pumps/?utm_source=rss&utm_medium=rss&utm_campaign=tb-series-pumps-submersible-pond-waterfall-pumps https://easypro.com/tb-series-pumps-submersible-pond-waterfall-pumps/#respond Tue, 18 Feb 2025 16:27:31 +0000 https://easypro.com/?p=65392 The Best Choice for water Features above 20′

The post TB Series Pumps , Submersible Pond & Waterfall Pumps appeared first on EasyPro Pond Products.

]]>
The Best Choice for water Features above 20′

The post TB Series Pumps , Submersible Pond & Waterfall Pumps appeared first on EasyPro Pond Products.

]]>
https://easypro.com/tb-series-pumps-submersible-pond-waterfall-pumps/feed/ 0
High Head TB Series Waterfall Pumps Instructions for Operation https://easypro.com/high-head-tb-series-waterfall-pumps-instructions-for-operation/?utm_source=rss&utm_medium=rss&utm_campaign=high-head-tb-series-waterfall-pumps-instructions-for-operation https://easypro.com/high-head-tb-series-waterfall-pumps-instructions-for-operation/#respond Tue, 18 Feb 2025 15:19:53 +0000 https://easypro.com/?p=65388 TB8000 • TB8002 • TB12000 • TB14500  Thank you for purchasing the TB series waterfall pump.This instruction manual explains the product operations and gives important precautions regarding its safe use. In order to use the product to maximum benefit, be sure to read the instructions thoroughly and follow them carefully. Specifications TB High Head Pump […]

The post High Head TB Series Waterfall Pumps Instructions for Operation appeared first on EasyPro Pond Products.

]]>
TB8000 • TB8002 • TB12000 • TB14500 

Thank you for purchasing the TB series waterfall pump.This instruction manual explains the product operations and gives important precautions regarding its safe use. In order to use the product to maximum benefit, be sure to read the instructions thoroughly and follow them carefully.

Specifications

  • 3″ outlets
  • Automatic thermal overload protection
  • Double silicone carbide mechanical seals with
  • 100,000 hour life expectancy
  • TB8000 available as 230v or 115v, TB12000 and TB14500 available as 230v only
  • Two year limited warranty
  • A minimum of 20′ head pressure required for TB12000 abd TB14500

TB High Head Pump Trouble Shooting 

Humming 

  • Line circuit breaker is off, fuse is burned or loose
  • Pump cord is not making contact in receptacle
  • Float (optional) is stuck, it should operate freely
  • May have air lock

Running, no water

  •  Check valve (optional) is installed backwards
  • Discharge shut-off valve closed
  • Inlet or impeller clogged
  • Pump is air-locked, start and stop several times by plugging and unplugging cord, check for clogged vent hole, may need to disconnect and reinstall pump.
  • Inlet holes in pump base are clogged, remove pump and clean the openings.
  • Vertical pumping distance is too high or the pipe
  • size is too small, reduce vertical distance or
  • increase the pipe size fittings.

Running, very little water

  • Pump is air-locked, start and stop several times byplugging and unplugging cord, check for clogged vent hole
  • Vertical pumping distance is too high or the pipe size is too small
  • Inlet or impeller clogged/damged
  • Low water conditions with pump sucking air

GFCI breaker tripping

  • Fuse size or circuit breaker may be too small.
  • Motor stator may be defective
  • Pump impeller or inlet is partially clogged with debris

Motor briefly starts and stops

  • Low water conditions, pump overheating
  • Inlet or impeller clogged
  • Improper power supply
  • Motor stator may be defective

Limited Warranty:

  • Pump is warranted against any mechanical or material defects for a period of two years from date of purchase
  • This warranty does not cover accidental damage to the product due to abuse or negligence by the consumer.
  • An RMA number must be obtained by calling EasyPro Pond Products at 800- 448-3873 and be included on package before returning for warranty.

Return warranty items to:

EasyPro Pond Products, 4385 East 110th, Grant, MI 49327 Be sure to include RMA number, original receipt, name, return address and phone number in package.

  • In the event of a warranty claim, please return the pump postage prepaid with the original receipt for repair or exchange. No warranty
  • claims will be honored without the original receipt.
  • The manufacturer or supplier shall not be held liable for any damages caused by defective components or materials of this pump; or forloss incurred because of the interruption of service; or any consequential/incidental damages and expenses arising from the production, sale, use or misuse of this product.
  • The manufacturer or supplier shall not be held liable for any loss of fish, plants or an other livestock as a result of any failure or defect of this product.
  • This pump must stay submerged entirely when operating. If used in skimmer, the debris net must be kept clean to ensure adequate water flow to the pump. Running pump lownon water will cause overheating and premature failure which is not covered under warranty.
  • If you experience a failure of your pump, please check the following before returning to us:
  1. Remove filter housing, clean and inspect impellar and surrounding chamber, reassemble and test pump;
  2. Verify electrical supply.

WARNING: 

The pump cannot be used for sea water, chlorinated water and flammable, corrosive, explosive or dangerous liquids.

Installation:

WARNING: 

  • Do not work on pump until power is unplugged.
  • Do not cut off ground pin or use an adapter fitting.
  • Do not use an extension cord
  • Must be used on a GFCI protected outlet
  • Do install the strainer prior to using if you want to let the pump run as a sump pump.

The pump power cord should be connected to a separately fused, grounded line with a minimum capacity of 15 amps. It can be connected to non- fuse breaker at the recommended amps. Never touch the pump when it is plugged in.

  1. Before installing or servicing this pump, be certain pump power source is disconnected. Contact a qualified licensed electrician for disconnecting electrical service prior to pump removal.
  2. Installation and electrical wiring must adhere to state/local codes and must be completed before priming pump. Check appropriate community agencies, or contact local electrical and pump professionals.
  3. Call an electrician when in doubt. Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block. Note that,plugging into existing outlets may cause low voltage at motor, causing blown fuses, tripping of motor overload or burned out motor.
  4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory. For maximum safety, connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump’s grounding wire.
  5. Voltage of power supply must match the voltage of the pump.

WARNING: 

Must be vented in accordance with local plumbing codes. EasyPro pumps are not designed for and CANNOT be installed in locations classified as hazardous.

WARNING: 

The following may cause severe damage to pump and

will void warranty:

  • Using an extension cord
  • Cutting off the ground pin or using an adapter fitting
  • Working on pump or switch while plugged in
  • Removing motor housing, unscrewing impeller or otherwise removing impeller seal
  • Pumping chemicals or corrosive liquids including chlorinated or salt
  • water
  • Pumping gasoline or other flammable liquids
  • Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe may all be used. All piping must be clean and free of all foreign matter to prevent clogging. Be sure to seal the thread connection with tape seal when you are using the pipe fitting to connect the flange.

Replacement Parts

Replacement Parts
chart table
chart table

Safety & Electrical Connections

WARNING: 

Verify that the voltage and frequency of the electric pump shown on nameplate correspond to those available on mains.

  • The installer must make sure that the electric system is grounded in accordance with local ordinances.
  • The plug and connections should be protected from water/rain. Before using the pump, always inspect it visually (especially power cable and plug).
  • Do not use the pump if it is damaged. If the pump is damaged, have it inspected by a qualified service center only.
  • Make sure electric connections are protected from all water and moisture. Protect plug and the power cable from heat, oil or sharp edges.

WARNING:

The power cable must be replaced by qualified personnel only.

Grounding: The plug of the power cable has a double grounding contact, so that grounding can be performed by simply inserting the plug.

Overload Protection: EasyPro pumps have a built in thermal protection switch. The pump stops if an overload condition occurs. The motor restarts automatically after it has cooled down.

Prior to Operation 

Check the following points upon receipt of your pump:

  • Is the pump exactly what you ordered? Check nameplate.
  • Has any damage occurred during shipment?
  • Are any bolts or nuts loose?
  • Have all necessary accessories been supplied?
  • We recommend that you keep a spare pump on hand in case of emergencies. Keep this instruction manual in a place for future reference.

Installation

Limitations: 

This series of pumps are suitable to pump water and also can be used both for permanent and temporary installation. The pump can be placed in a sump pit, then can pump dirty water containing suspended solid particles up to 1 /2″ diameter.

The post High Head TB Series Waterfall Pumps Instructions for Operation appeared first on EasyPro Pond Products.

]]>
https://easypro.com/high-head-tb-series-waterfall-pumps-instructions-for-operation/feed/ 0
Check Valve Assembly Instructions CVA30K-CVA30K9 https://easypro.com/check-valve-assembly-instructions-cva30k-cva30k9/?utm_source=rss&utm_medium=rss&utm_campaign=check-valve-assembly-instructions-cva30k-cva30k9 https://easypro.com/check-valve-assembly-instructions-cva30k-cva30k9/#respond Tue, 18 Feb 2025 14:30:09 +0000 https://easypro.com/?p=65386 Assembly is cut to length and glued on-site, check valve installs outside skimmer.  *Picture displayed is for reference only, actual product or application may vary.  CVA30K Compatible with – TB8000, TB12000, TM9500, TM13500 1. 3″ Male Adapter 2. 10″ Long – 3″ PVC Pipe 3. 3″ Elbow 4. 3 3/4″ Long – 3″ PVC Pipe […]

The post Check Valve Assembly Instructions CVA30K-CVA30K9 appeared first on EasyPro Pond Products.

]]>
Assembly is cut to length and glued on-site, check valve installs outside skimmer. 

*Picture displayed is for reference only, actual product or application may vary. 

  1. All PVC fittings must be primed and glued. 
  2. Properly tighten hose clamps on rubber coupler. 
  3. Check valve must be installed with correct flow and vertical orientation
Check Valve Assembly Instructions

CVA30K

Compatible with – TB8000, TB12000,

TM9500, TM13500

1. 3″ Male Adapter

2. 10″ Long – 3″ PVC Pipe

3. 3″ Elbow

4. 3 3/4″ Long – 3″ PVC Pipe

5. 3″ Rubber Coupler

6. 3″ x 3″ Nipple

7. 3″ x 3″ Nipple

8. 3″ Check Valve

CVA30K

CVA30K9

Compatible with – EP9700

1. 2″ Female Adapter

2. 2″ Long – 2″ PVC Pipe

3. 2″ x 3″ Reducer Bushing

4. 3″ Coupler

5. 3″ Long – 3″ PVC Pipe

6. 3″ Elbow

7. 5″ Long – 3″ PVC Pipe

8. 3″ Rubber Coupler

9. 3″ x 3″ Nipple

10. 3″ x 3″ Nipple

11. 3″ Check Valve

CVA30K9

The post Check Valve Assembly Instructions CVA30K-CVA30K9 appeared first on EasyPro Pond Products.

]]>
https://easypro.com/check-valve-assembly-instructions-cva30k-cva30k9/feed/ 0
Installation Instructions for Tempo Submersible Pond Filters https://easypro.com/installation-instructions-for-tempo-submersible-pond-filters/?utm_source=rss&utm_medium=rss&utm_campaign=installation-instructions-for-tempo-submersible-pond-filters https://easypro.com/installation-instructions-for-tempo-submersible-pond-filters/#respond Tue, 18 Feb 2025 14:07:54 +0000 https://easypro.com/?p=65377 The Tempo filter is a heavy duty submersible filter that is great for water gardens up to 600 gallons total capacity. The filter provides mechanical and biological filtration. Position your Tempo submersible filter in the deepest part of your pond, as far away from your waterfallas possible. We recommend using the Eco-Series universal waterfall diffuser […]

The post Installation Instructions for Tempo Submersible Pond Filters appeared first on EasyPro Pond Products.

]]>
The Tempo filter is a heavy duty submersible filter that is great for water gardens up to 600 gallons total capacity. The filter provides mechanical and biological filtration.


Position your Tempo submersible filter in the deepest part of your pond, as far away from your waterfallas possible. We recommend using the Eco-Series universal waterfall diffuser or the Eco-Series waterfallspillways to help you create a beautiful, leak proof waterfall.

Installation Instructions for
Tempo Submersible Pond Filters

INSTALLING TEMPO FILTER

Place pump in bottom chamber of filter. We recommend EasyPro mag drive pumps up to 850 GPH. 

1

Thread electrical cord through hole in base of filter. Always plug pumps into a GFI outlet.

2

Slide tubing through big hole in base of filter. Use 1 /2″ to 1″ tubing.

3

Insert the white inner media

4

Replace the black top pad.

5

Place filter in lowest part of pond, opposite the waterfall for best circulation.

6

CLEANING TEMPO FILTER 

  1. Thoroughly rinse the top pad once a week or as needed depending on pond conditions. 
  2. Unroll and clean the inner pad monthly. Size of pond, fish load and other factors will determine exactly how often you will need to clean the filter.

 Replacement Pads Available: WF6TP – top pad, WF6BP – bottom inner pad 

EasyPro products are designed to work independently or with sister products like our water treatment line. See our website easypropondproducts.com/water-treatments for more information.

CLEANING TEMPO FILTER

The post Installation Instructions for Tempo Submersible Pond Filters appeared first on EasyPro Pond Products.

]]>
https://easypro.com/installation-instructions-for-tempo-submersible-pond-filters/feed/ 0
Pro Clear Aire Compressors Data Sell Sheet https://easypro.com/pro-clear-aire-compressors-data-sell-sheet/?utm_source=rss&utm_medium=rss&utm_campaign=pro-clear-aire-compressors-data-sell-sheet https://easypro.com/pro-clear-aire-compressors-data-sell-sheet/#respond Mon, 17 Feb 2025 21:47:23 +0000 https://easypro.com/?p=65371 AERATION COMPRESSORS GREAT FOR AERATING PONDS WATER FEATURES HYDROPONICS FISH TANKS Improve water quality with the benefits of aeration!  Designed for the demanding job of 24 hour operation. The oil-less design makes them ideal for pond aeration.

The post Pro Clear Aire Compressors Data Sell Sheet appeared first on EasyPro Pond Products.

]]>

Pro-ClearAireCompressors_Data-SellSheet_EasyPro-1

AERATION COMPRESSORS

  • Quiet, energy-efficient operation 
  • Dual linear diaphragm design for maximum air flow n Few moving parts – simple routine maintenance 
  • Units available to aerate 1,000 to 30,000 gallons 
  • Aluminum housing dissipates heat for longer product life 
  • No electricity in the water – safe for fish, pets and family

GREAT FOR AERATING PONDS WATER FEATURES HYDROPONICS FISH TANKS

Improve water quality with the benefits of aeration! 

Designed for the demanding job of 24 hour operation. The oil-less design makes them ideal for pond aeration.

Improve water quality with the benefits of aeration!
compressor performance data

The post Pro Clear Aire Compressors Data Sell Sheet appeared first on EasyPro Pond Products.

]]>